Each EDAS-2008M-1 Serial Port Module provides four RS-232 serial ports. The serial ports are interfaced through 9-pin D-subminiature connectors on the bottom of the unit.
The EDAS-2000E-1/-2/-3 base units can support up to six EDAS-2008M-1 Serial Port Modules for a total of twenty-five COM ports, one COM port located on the base unit and twenty-four COM ports on the six Serial Port Modules.
Click here to request more information about the EDAS CE system
to view pricing of EDAS-2008M-1, click here
| Serial Port Module: EDAS-2008M-1 | ||
|---|---|---|
| Parameter | Conditions | Specifications |
| Serial
RS-232C Connector Communication Supply Voltages Baud Rate |
3K ohm load |
4 Ports
DE-9 ASCII, Binary ± 6V TX, RTS Active 300 - 115K Baud |
| Serial Output
Output Voltage Low Output Voltage High |
3K ohm load
3K ohm load |
-5.0V max
+5.0V min |
| Serial Inputs
Input Impedance Input Threshold Low Input Threshold High |
3K ohm min, 7K ohm max
.08V min 2.4V max |
|
| Current Consumption | 5VDC | 200 mA max |
| Dimensions | Inches
mm |
4.55D x 5.9H x 1.74W
116D x 150H x 42W |
| Operating Temperature Range | 0 to 60° C* | |
| *All specifications are typical at 25° C unless otherwise noted. | ||
Copyright 1996-2009 Intelligent Instrumentation Inc.